TRIPP-LITE UPS 1.5kVa SMX1500LCDT SmartPro 230V 1.5kVA 900W Line-Interactive UPS Tower LCD USB 8 Outlet 2 Years Warranty
$13.43
$23.5
TRIPP-LITE UPS 1.5kVa SMX1500LCDT SmartPro 230V 1.5kVA 900W Line-Interactive UPS Tower LCD USB 8 OutletOverviewThe SMX1500LCDT SmartPro® 230V 1.5kVA 900W Line-Interactive UPS provides battery backup and AC power protection against blackouts, brownouts, power surges and line noise that can damage electronics or destroy data. Ideal for backing up home/office workstations, media centers and home entertainment systems, the SMX1500LCDT switches to battery mode in milliseconds to keep your connected equipment running long enough to save files and shut down safely with no data loss.Featuring eight IEC-320-C13 outlets and a C14 inlet that accepts a user-supplied AC power cord, the SMX1500LCDT has an internal battery that provides 10 minutes of support at half load. It can also power an entry-level PC up to 90 minutes. Two of the eight outlets provide surge protection only for printers and other non-essential devices A front-panel LCD screen lets you configure settings and monitor operating data, such as voltage, battery and load statuses.Automatic voltage regulation (AVR) maintains 230V nominal output over an input range of 170V to 280V without using battery power. EMI/RFI noise filtering improves your equipment’s performance and prevents damage. A 455-joule surge suppression rating protects your equipment from harmful power surges. With free downloadable PowerAlert® software, SMX1500LCDT enables safe unattended system shutdown in case of a prolonged power failure.FeaturesProtects Mission-Critical EquipmentProvides fully regulated AC output for home/office workstations, media centers and home entertainment systemsAudible alarm signals loss of utility power or low battery8 C13 outlets—2 surge-onlyC14 inlet accepts user-supplied AC power cord with country-specific plug455-joule surge suppression ratingReliable Battery BackupSupports half load up to 10 min.Powers entry-level PC up to 90 min.Internal batteries designed for hot-swap field replacement95% line-power efficiency rating saves money in energy costsCold-start capability enables turn-on in battery mode during blackoutsAutomatic Voltage Regulation (AVR)Maintains 230V nominal output over input range of 170V–280V without using battery powerEMI/RFI Line Noise FilteringRemoves electromagnetic and radio frequency interference that can disrupt or damage equipment’s performanceInteractive LCD ScreenFront-panel LCD signals voltage, battery and load statusesSupports multiple advanced user setup and operating preferencesCommunications PortUSB port enables data-saving unattended shutdown when used with PowerAlert software, available via FREE download from tripplite.eaton.com/products/power-alertRJ45 Telephone/Ethernet Protection JacksProtect phone/DSL/fax/modem/Ethernet network against power surgesPackage IncludesSMX1500LCDT SmartPro 230V 1.5kVA 900W Line-Interactive UPSUSB cableC13-to-C14 power cableOwner’s manualAccessories for UPS Battery BackupWe have a range of accessories designed to work with our UPS Battery Backup. Check them out!SpecificationsOVERVIEWUPC Code037332177445UPS TypeLine-InteractiveINPUTInput PhaseSingle-PhaseRated input current (Maximum Load)9ANominal Input Voltage(s) Supported230V ACUPS Input Connection TypeC14 inletInput Circuit Breakers10A fuseUPS Input Cord Length (ft.)6Input Frequency±3HzOUTPUTOutput Capacity (VA)1500Output Capacity (kVA)1.5Output Capacity (Watts)900Output Capacity (kW)0.9Output Capacity Details6.5 A @ 230 V~Power Factor0.6Nominal Voltage Details230V nominal output in battery modeFrequency Compatibility50 / 60 HzFrequency Compatibility DetailsAutomatic frequency selectionOutput Voltage Regulation (Line Mode)230V~ ( 7% / – 12.8%)Output Voltage Regulation (Battery Mode) /- 5%UPS Output Receptacles (Surge Suppression Only)6 UPS outlets, 2 surge-only outletsHot-Swap PDU optionsPDUBHV10 (2U / 8 C13 outlets)Output AC Waveform (AC Mode)Sine waveOutput AC Waveform (Battery Mode)PWM sine waveNominal Output Voltage(s) Supported220V; 230V; 240VOutput Receptacles(8) C13BATTERYBattery TypeValve Regulated Lead Acid (VRLA)Runtime Full Load (min.)1.96 min. (900W)Runtime Half Load (min.)9.96 min. (450W)DC System Voltage (VDC)24Battery Recharge Rate (Included Batteries)10.1 hours from 10% to 90%Internal UPS Replacement Battery Cartridge RBC51 (requires 2)VOLTAGE REGULATIONVoltage Regulation DescriptionAutomatic voltage regulation (AVR) maintains line power operation with a correction range from 170V to 280VOvervoltage CorrectionInput voltages between 247 and 280 are reduced by 15%Undervoltage CorrectionInput voltages between 170 and 207 are boosted by 18%USER INTERFACE, ALERTS & CONTROLSFront Panel LCD DisplayLCD screen with scroll buttons indicates Input voltage, Output voltage, Frequency (Hz), AVR boost / cut status, Output load in watts, Output load percentage, Output load in watts, Battery voltage and Estimated runtime in minutesSwitchesPower switch offers whole UPS power control; Scroll/mute button enables LCD selection options and silences audible alarm; Test button initiates self testAlarm Cancel OperationPower-fail alarm can be silenced using alarm-cancel switchAudible AlarmAudible alarm indicates power-failure and low-battery conditionsSURGE / NOISE SUPPRESSIONUPS AC Suppression Joule Rating455UPS AC Suppression Response TimeInstantaneousUPS Dataline Suppression1 line TEL/DSL (1 in / 1 out); 10/100Base T EthernetEMI / RFI AC Noise SuppressionYesPHYSICALPrimary Form FactorTowerCooling MethodFanInstallation Form Factors Supported with Included AccessoriesTowerPrimary UPS Depth (mm)394Primary UPS Height (mm)203Primary UPS Width (mm)146Shipping Dimensions (hwd / in.)11.30 x 9.10 x 19.30Shipping Weight (lbs.)27.20UPS Power Module Dimensions (hwd, in.)8 x 5.75 x 15.5UPS Power Module Weight (kg)11.20UPS Power Module Weight (lbs.)24.7Unit Weight (lbs.)24.7000ENVIRONMENTALOperating Temperature Range32° to 104°F (0° to 40°C)Storage Temperature Range5° to 122°F (-15° to 50°C)Relative Humidity0 to 95%, non-condensingAC Mode BTU / Hr. (Full Load)79AC Mode Efficiency Rating (100% Load)95�ttery Mode Heat Dissipation (BTU/Hr) @ Full Load918COMMUNICATIONSNetwork Monitoring Port DescriptionSupports detailed monitoring of UPS and site power conditionsPowerAlert SoftwareFor local monitoring via the UPS’s built-in communication ports, download PowerAlert software at https://tripplite.eaton.com/products/power-alertCommunications CableUSB cabling includedWatchDog CompatibilitySupports Watchdog application, OS and hard-reboot restart options for remote applicationsNetwork Management Card DescriptionNetwork management not supportedCommunications InterfaceUSB (HID enabled)LINE / BATTERY TRANSFERTransfer Time6 millisecondsLow Voltage Transfer to Battery Power (Setpoint)170V (factory setting), 175V (medium setting), 180V (narrow setting)High Voltage Transfer to Battery Power (Setpoint)280V (factory setting), 275V (medium setting), 270V (narrow setting)FEATURES & SPECIFICATIONSCold Start (Startup in Battery Mode During a Power Failure)Cold-start operation supportedHigh Availability UPS FeaturesAutomatic Voltage Regulation (AVR); Hot swappable batteries; Surge/noise protectionGreen Energy-Saving FeaturesGreater than 95% efficiency – GREEN UPSAPPLICATIONSUPS ApplicationsHome/Office Desktop; Audio/VideoSTANDARDS & COMPLIANCEProduct CertificationsGOST (Russia); EN 62040-1; EN 62040-2Product ComplianceRoHS; SASO (Saudi Arabia); CE (Europe)Today’s Promotion ON✅ Contact for Latest Price
Ups Battery